AURAMAX FZC



Cooling Pads & Air Cooler Spare Parts in Dubai UAE

Auramax FZC supplies replacement cooling pads, water pumps, motors, fan blades, and all key spare parts for industrial and commercial air coolers in Dubai and across the UAE. Cooling pads are the most frequently replaced component in an evaporative air cooler — they need to be replaced when clogged with mineral deposits, algae, or physical damage to maintain full cooling efficiency. We stock standard cellulose and synthetic cooling pads in all common sizes for UAE-market air coolers. For detailed guidance on maintaining your cooler, see our article on air cooler water pump replacement in UAE.

Product Specifications — UAE Models

Component Description
Cellulose Cooling Pads High-density cellulose honey-comb pads — 60mm, 100mm and 150mm thickness options
Synthetic Cooling Pads Rigid plastic/fibre synthetic pads — longer life than cellulose, ideal for hard water areas
Pad Sizes Available 300x300mm to 900x900mm — cut to size available for non-standard dimensions
Water Pumps Replacement submersible water pumps — 220V, various flow rates from 300–1,200 litres/hour
Fan Motors Direct replacement fan motors — single phase 220V, various power ratings
Fan Blades Plastic and aluminium replacement fan blades — multiple diameter options
Float Valves Automatic water level control float valve replacements
Distribution Headers Water distribution pipe and nozzle sets for even pad saturation

Key Benefits

  • Replace cooling pads annually for maximum cooling efficiency in UAE's hard water environment
  • Hard water in Dubai causes rapid mineral scaling — synthetic pads last longer in hard water areas
  • Compatible with all major brands of industrial and commercial air coolers (full air cooler range)
  • Bulk pad supply available for facilities with large cooler fleets
  • Water pump replacement extends cooler life significantly — prevents burn-out from scale build-up

Applications in the UAE

Application Description
Annual Maintenance Replace cooling pads and check water pump at the start of each UAE cooling season (April)
Performance Restoration Replacing blocked or damaged pads immediately restores full cooling output
Hard Water Treatment In Dubai's hard water areas, descaling pads or using synthetic pads reduces replacement frequency
Post-Summer Storage Clean and dry pads before summer end storage to prevent mould and algae growth

Frequently Asked Questions

How often should air cooler cooling pads be replaced in UAE?
In UAE conditions with hard tap water, cooling pads should be replaced every 1–2 seasons (12–24 months) depending on water quality and usage frequency. If you notice significant mineral build-up, reduced cooling output, or physical damage to the pad structure, replacement is required immediately.
What is the best cooling pad for Dubai's hard water?
Synthetic rigid media cooling pads are recommended for Dubai and UAE where tap water has high mineral content. They are more resistant to scale build-up, easier to clean, and last 2–3x longer than standard cellulose pads in hard water conditions.
Can you supply cooling pads cut to a specific size?
Yes. Auramax FZC can supply cooling pads cut to custom sizes for non-standard air cooler dimensions. Contact our Dubai team with the pad dimensions required (height, width, thickness) and we will supply accordingly.